RCM series
The RCM series monitors for faults on grounded and high-resistance grounded systems running on AC or pulsed DC (IEC 60755 Type A) power.
Compare up to three products side by side:
 |
|
RCM470LY |
 Ground fault monitor for grounded AC systems
|
|
The RCM470LY monitors for ground fault leakage current in grounded & high-resistance grounded single & three-phase AC systems and pulsed DC type systems (Type A). Features include adjustable setpoint from either 6mA...600mA or 10mA…10A, LED meter display (0-100%), adjustable time delay from 0...10sec, fault storage, 1 DPDT alarm relay which can be set for normally energized and normally de-energized operation. An external BENDER current transformer is required for operation.
|
|
| |
|
 |
|
RCM475LY |
 Ground fault monitor for grounded AC systems with internal CT
|
|
The RCM475LY monitors for ground fault leakage current in grounded & high-resistance grounded single & three-phase AC systems and pulsed DC type systems (Type A). Features include adjustable setpoint from either 6mA...600mA or 10mA…10A, LED meter display (0-100%), adjustable time delay from 0...10sec, fault storage, 1 DPDT alarm relay which can be set for normally energized and normally de-energized operation. Includes a built-in 18mm current transformer.
|
|
| |
|
 |
|
RCM460Y |
 Ground fault monitor for grounded AC systems
|
|
The RCM460Y monitors for ground fault leakage current in grounded and high-resistance grounded single and three-phase AC and pulsed DC systems (Type A). Features include adjustable setpoint from 30mA...300mA, adjustable time delay from 0...1 s, 1 DPDT alarm relay which can be set for normally de-energized operation. An external BENDER current transformer is required for operation.
|
|
| |
|
 |
|
RCM465Y |
 Ground fault monitor for grounded AC systems with internal CT
|
|
The RCM465Y monitors for ground fault leakage current in grounded and high-resistance grounded single and three-phase AC and pulsed DC systems (Type A). Features include adjustable setpoint from 30mA...300mA, adjustable time delay from 0...1 s, 1 DPDT alarm relay which can be set for normally de-energized operation. Includes a built-int 18mm current transformer.
|
|
| |
|
 |
|
RCM420 |
 Digital Ground fault monitor for grounded AC systems
|
|
The RCM420 monitors for ground fault leakage current in grounded & high-resistance grounded single & three-phase AC systems and pulsed DC type systems (Type A). Features include adjustable setpoint from 10mA…10A, LCD display, adjustable time delay, fault storage, 2 SPDT alarm relays which can be set for normally energized and normally de-energized operation. An external BENDER current transformer is required for operation.
|
|
| |
|
 |
|
RCM475YM2 |
 Ground fault monitor for grounded AC systems
|
|
The RCM475YM2 monitors for ground fault leakage current in grounded and high-resistance grounded single and three-phase AC and pulsed DC systems (Type A). Features include two seperately adjustable response values to distinguish between pre-warning and alarm, adjustable time delay, fault storage, 2 DPDT alarm relays which can be set for normally energized and normally de-energized operation. Includes a built-in 18mm current transformer.
|
|
| |
|
|
 |