    Ground fault location module for ungrounded AC/DC systems

    Compatible with IRDH575

    The EDS490 ground fault location module, in combination with the IRDH575 ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS490 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS490 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS490 is used with the IRDH575 ground detector and is designed for large power distribution networks. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS490 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS490 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Systems with power conversion components, including rectifiers and inverters
    • Large industrial systems
    • Ungrounded systems with high leakage capacitances
  • Ordering information: EDS490 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS490-D-12 - 10 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080009
    EDS490-D-22 - 10 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080010
    EDS490-L-12 - 10 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080011
    EDS490-L-22 - 10 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080012
  • Downloads: EDS490 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    User Manual
    Modbus TCP Integration
    English 12.2016
    Download
    Brochure
    Overview of Products
    English 06.2017
    Download
  • Accessories: EDS490 Series

    Remote Communication Systems

    Ethernet and Modbus/TCP communication gateway for BENDER devices

    NameOrdering Number
    COM465IP-230VB95061065
    COM465IP-24VB95061066
    COM461MTB95061021
    COM462RTUB95061022
    AC Current Transformers

    Current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    W0-S20B911787
    W1-S35B911731
    W2-S70B911732
    W3-S105B911733
    W4-S140B911734
    W5-S210B911735
    Rectangular AC Current Transformers

    Rectangular current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WR70x175SB911738
    WR115x305SB911739
    WR115x350SB911740
    WR200x500SB911763
    WR70x175SPB911790
    WR115x305SPB911791
    WR115x350SPB911792
    WR200x500SPB911793
    Split-Core AC Current Transformers

    Split-core current transformers for RCM and RCMS series ground fault monitors (AC only systems)

    NameOrdering Number
    WS20x30B98080601
    WS50x80B98080603
    WS80x120B98080606
  • Description
  • Features
  • Applications
  • Ordering Info
  • Downloads
  • Accessories
  • EDS491 Series

    Ground fault location module for small ungrounded AC/DC systems

    Compatible with IRDH575 and LIM2010

    The EDS491 ground fault location module, in combination with the appropriate ground fault detector, locates branch faults in ungrounded AC/DC systems. Up to 12 separate branches may be monitored by one EDS491 device. Up to 90 EDS devices may be connected together, for a total of 1080 branches simultaneously monitored. The EDS491 works on both AC and DC systems, including systems with variable frequency drives (VFDs). Devices are interconnected via RS-485 to automate the process of locating faults. An LCD display shows which branch has the ground fault after it has been located. One common DPDT contact is built into the EDS490, along with twelve separate SPST contacts, one for each channel.

    The EDS491 is used with the IRDH575 ground detector or LIM2010 line isolation monitor, and is designed for small control networks or isolated power systems. It features a common DPDT contact output and twelve SPST contact outputs, one for each channel.

  • Key Features: EDS491 Series

    • Ground fault location in ungrounded AC/DC systems, when combined with IRDH575 or LIM2010 ground detector
    • Up to 12 separate branches monitored from one device
    • All channels scanned in parallel
    • Works on pure AC, pure DC, and mixed AC/DC systems, including systems with variable frequency drives (VFDs)
    • Digital display showing readings in real-time
    • Easy-to-use, onboard menu for managing settings
    • Devices linked via RS-485 display alarm values across all interconnected devices
    • Automatic ground fault detection and location with IRDH575 via RS-485
    • Automatic self-test
    • Built-in test and reset buttons
    • Connections for external test and reset
    • Latching or non-latching operation, selectable
    • One common DPDT contact outputs, normally energized or normally de-energized operation
    • 12 Additional SPST contacts, one for each channel, N/O or N/C
    • History memory storing up to 300 timestamped events in non-volatile memory
  • Applications: EDS491 Series

    • AC systems, single- and three-phase
    • Pure DC and mixed AC/DC systems
    • Distribution systems requiring fast ground fault location
    • UPS systems and battery systems
    • Systems with variable frequency drives (VFDs)
    • Control networks and small distribution systems
    • Isolated power systems for healthcare facilities
  • Ordering information: EDS491 Series

    NameResponse ValueDisplay typeSupply VoltageOrdering Number
    EDS491-D-10.2 - 1 mA DigitalAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080013
    EDS491-D-20.2 - 1 mA DigitalAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080014
    EDS491-L-10.2 - 1 mA AnalogAC 16 - 72 V (42 - 460 Hz) DC 16 - 94 V B91080015
    EDS490-L-20.2 - 1 mA AnalogAC 70 - 276 V (42 - 460 Hz) DC 70 - 276 V B91080016
  • Downloads: EDS491 Series

    Document Name Language Date Download
    Technical Bulletin / Datasheet
    EDS460 / EDS490 Series
    English 03.2011
    Download
    Installation Bulletin
    EDS460 / EDS490 Series
    English 10.2011
    Download
    User Manual
    EDS460 / EDS490 Series
    English 03.2011
    Download
    User Manual
    Modbus TCP Integration
    English 12.2016
    Download
    Brochure
    Overview of Products
    English 06.2017
    Download
    Brochure
    Isolated Power Systems Equipment
    English 10.2011
    Download
  • Accessories: EDS491 Series

    AC Current Transformers

    Current transformers for use with EDS461/EDS491 ground fault location modules

    NameOrdering Number
    W20-8000B98080009
    W35-8000B98080017
    W60-8000B98080027