Isolated Power Systems and Accessories


Need assistance in building the right Isolated Power solution? Try out our new Isolated Power Solution Builder.



Isolated Power Panel (IPP)


Description:

  • Applications - Single and three phase systems
  • Power Distribution - Loadcenter available with plug-on or bolt-on circuit breakers
  • Mounting - Available for flush or surface mounted applications
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM) features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




Isolated Power Center (IPC)


Description:

  • Applications - Single phase systems
  • Power Distribution - Loadcenter available with plug-on or bolt-on circuit breakers
  • Outlet Devices - Up to eight gang arrangement of power receptacles and ground jacks
  • Mounting - Available for flush or surface mounted applications
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM) features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




Surgical Facility Center (SFC)


Description:

  • Applications - Single phase systems
  • Power Distribution - Loadcenter available with plug-on or bolt-on circuit breakers
  • Outlet Devices - Up to eight power receptacles and ground jacks
  • Features - two section X-Ray Viewer, digital clock/elapsed timer, AM/FM stereo with cassette and/or CD player
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM) features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




X-Ray / Laser Power Centers (XPC / LPC)


Description:

  • Applications - Single and three phase systems
  • Power Distribution - Loadcenter available with plug-on or bolt-on circuit breakers, Lug-to-lug circuit breakers
  • Control Device - Programmable Logic Controller (PLC), Local and/or Remote Control Stations for up to 12 single receptacles
  • Mounting - Available for flush or surface mounted applications
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM)features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




Isolated Power Panels Dual System (IPPDS)


Description:

  • Applications - Single phase systems
  • Power Distribution - Dual loadcenters for dual sets of plug-on or bolt-on circuit breakers
  • Mounting - Available for flush or surface mounted applications
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM) features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




Isolated Power Panels Dual Voltage (IPPDV)


Description:

  • Applications - Single phase systems
  • Power Distribution - Dual loadcenters available for dual sets of plug-on or bolt-on circuit breakers, Lug-to-lug circuit breakers
  • Mounting - Available for flush or surface mounted applications
  • Advanced Technology - The BENDER LIM2000plusTM Line Isolation Monitor (LIM) features self-test, self-calibration and optional load monitoring
  • Standards - UL 1047 - Isolated Power Systems Equipment
  • Warranty - Industry's first 5 year limited warranty


Technical Specs Brochure




X-Ray / Laser Receptacle Module (XRM / LRM)


Description:

  • Applications - Receptacle Modules with flush or surface mounted receptacles for use with X-Ray/Laser Power Centers 
  • Mounting - Available for flush or surface mounted applications
  • Options - Available with: door contacts, "In-Use" Lamps, BENDER LIM Remote Indicators
  • Standards - UL Listed Product (UL 1047)


Technical Specs Brochure




Remote Annunciator Station (RAS)


Description:

  • Applications - Multiple LIM Remote Indicators for Central Monitoring of Isolated Power Systems
  • Mounting - Available for flush or surface mounted applications
  • Standards - UL Listed Product (UL 1047)


Technical Specs Brochure




Remote Control Station (RCS)


Description:

  • Applications - Remote Control and Monitoring Station for X-Ray / Laser Isolated Power Centers with Programmable Logic Controller (PLC)
  • Mounting - Available for flush or surface mounted applications
  • Options - Available with: BENDER LIM Remote Indicators
  • Standards - UL Listed Product (UL 1047)


Technical Specs Brochure