Bender WorldwideSite Map

Home

Products

Success Stories

About Us

Resources

What's New

Contact Us













 
Ground fault monitors for ungrounded AC, 3(N)AC, and DC main systems
These insulation monitors are designed to monitor ungrounded AC and DC systems on a large scale.

Compare up to three products side by side:

IR470LY
Ground Fault Monitor for Ungrounded Single- and Three-Phase AC systems up to 793 V
The IR470LY series monitors the insulation resistance of ungrounded AC and 3(N)AC systems from 0 to 793 V. Connecting a voltage coupler allows systems of higher voltages to use this device. The resistance level is set via a potentiometer and DIP switch.
 Technical Specs                 Datasheet


IR475LY
Ground Fault Monitor for Ungrounded Single-, Three-Phase AC and DC systems up to 693 V AC / 400 V DC
The IR475LY series monitors the insulation resistance of ungrounded AC, 3(N)AC, and DC systems from 0 - 693 V AC, 3NAC and 0 - 400 V DC. Connecting a voltage coupler allows systems of higher voltages to use this device. Two seperate alarms for a pre-warning and true alarm are settable via potentiomters and DIP switches.
 Technical Specs                 Datasheet


IRDH275
Ground Fault Monitor for Ungrounded Single-, Three-Phase AC and DC systems up to 793 V AC / 650 V DC
The IRDH275 series monitors the insulation resistance of ungrounded AC, 3(N)AC and AC/DC systems from 0 to 793 V AC and 0 to 650 V DC. The AMP Plus measuring principle meets the requirements of modern power supplies, which often include rectifiers, converters, and directly connected DC componenets. In systems with high leakage capacitances, the IRDH275 automatically adapts itself to the existing system conditions. Connecting a voltage coupler allows the unit to be placed in higher-voltage systems.

Preferences are set via a digital display and buttons. An external supply voltage allows de-energized systems to be monitored as well.
 Technical Specs                 Datasheet


IRDH375
Ground Fault Monitor for Ungrounded Single-, Three-Phase AC and DC systems up to 793 V AC / 650 V DC
The IRDH375 series monitors the insulation resistance of ungrounded AC, 3(N)AC and AC/DC systems from 0 to 793 V AC and 0 to 650 V DC. The AMP Plus measuring principle meets the requirements of modern power supplies, which often include rectifiers, converters, and directly connected DC componenets. In systems with high leakage capacitances, the IRDH275 automatically adapts itself to the existing system conditions. Connecting a voltage coupler allows the unit to be placed in higher-voltage systems.

Preferences are set via a digital display and buttons. An external supply voltage allows de-energized systems to be monitored as well. The IRDH375 series is designed to be panel-mounted into distribution panels.
 Technical Specs                 Datasheet


700 Fox Chase - Coatesville PA 19320 USA
Phone: 610-383-9200 / Fax: 610-383-7100 - Toll Free: 1-800-356-4266
To request more information, use our online form
or email us at: info@bender.org